Thursday, December 6, 2012

Film Coefficient of Friction Tester(COF Tester)


ASTM D1894 Standard Test Method for Static and Kinetic Coefficients of Friction of Plastic Film and Sheeting
MXD-01A Film Coefficient of Friction Tester(COF Tester)  is strictly based on ASTM D1894 standard, and is professional applicable to test static and kinetic coefficients of friction of plastic films, sheets, rubber, paper and paper board, PP woven bags, fabrics, metal-plastic composite belts for communication cables, convey belts, wood, coatings, brake pads, windshield wipers, shoe materials and tyres. By testing the frictional properties of materials, the technical indexes could be controlled to meet requirements for production. Besides, the instrument is available for the smoothness test of cosmetics, eye drops and other daily products.

Professional Technology:
  • Static and Kinetic coefficients of friction can be tested simultaneously
  • 
    Film Coefficient of Friction Tester(COF Tester)
    Film Coefficient of Friction Tester(COF Tester)
    
  • The functions of automatic delay timing and automatic COF zeroing ensure enough touching time between tested specimens
  • The sliding plane and the sled are treated by degaussing and remanence detection which effectively reduce the system errors
  • Film Coefficient of Friction Tester(COF Tester)  is controlled by micro-computer with LCD, PVC operation panel and menu interface, which is convenient for customers to test or view the test data

  • Applications:
    • Films
    • Paper and Paperboard
    • Textiles, Non-woven Fabrics and Woven Bags
    • Rubber
    • Aluminum Foil, Aluminum Foil Composite Films, and Metal Products
    • Printing Matters
    Technical Specifications:
    • Test Range:0 ~ 5 N
    • Accuracy:1% of Reading Value
    • Stroke:≥130 mm
    • Test Speed:
    Film Coefficient of Friction Tester(COF Tester)  conforms to the standard: ASTM D1894 
    Film Coefficient of Friction Tester(COF Tester)
    Film Coefficient of Friction Tester(COF Tester)
    
     Labthink,Think for you only!

    

    Wednesday, December 5, 2012

    Oxygen Permeability, OTR of Contact Lenses Materials

    Speaking of contact lenses, the most common thing we thought of is their contact' effect. Contact lenses correct vision by directly adhering to the surface of eye cornea to change diopter. Therefore, they possess a lot of unique merits comparing with frame glasses. For example, it applies no compression to nose bridge and ears, and is especially applicable to some special professions such as actor and athlete. Actually, the functions of contact lenses are not limit to the correction of shortsightedness, farsightedness and astigmatism. They have other functions such as treating color blindness and some ophthalmocace by medication absorption.

    1. Material Requirements of Contact Lens
    Wearers attach particular importance to the selection of lens material because it adheres directly to eye cornea. With the influence of advertisement, many wearers go in for lenses of high moisture content in selecting contact lenses. In their eyes, the higher the moisture content, the better the lens quality. In fact, the pursuit of higher moisture content is very wrong in contact lens selection. Wearers should also take secretory volume of tears, working and living environment into account. Actually, oxygen permeability of lenses is the most important index. The discomforts and wearing time mainly depends on lens oxygen permeability. Moreover, higher moisture content and ultra thin that are advertised now are to improve lens oxygen permeability.
    Oxygen deficit, which is caused by inability of eye cornea to obtain oxygen, is the most common trouble of wearing contact lenses. Originally, cornea breathes by obtaining oxygen from air directly. When contact lens adheres to eyeball surface, oxygen can still transmits through lenses, but the transmitting rate reduces obviously. Newly increased vessel caused by cornea oxygen deficit will appear as red heron and will increase the opportunity of infection of eyes. For that reason, contact lenses of higher oxygen permeability should be selected. Oxygen permeability of lenses is related with lens moisture content and lens thickness because oxygen is transmitted by water. However, the crucial factor that influences wearing effect is whether contact lenses match eye cornea.
    
    Oxygen Permeability Tester
    0X2/230 Oxygen Permeability Tester
    

    2. Oxygen Permeability Testing
    As mentioned above, oxygen permeability of contact lenses has a direct influence on wearer comforts and will in turn affect the sales. That is why oxygen permeability testing attracts particular attention of lens manufacturers.
    ISO issued special testing standards for the oxygen permeability testing of contact lenses: ISO 9913-1 Optics and Optical Instruments-Contact Lenses-Part 1: Determination of Oxygen Permeability and Transmissibility with the FATT Method and ISO 9913-2 Optics and Optical Instruments -Contact Lenses-Part2: Determination of Oxygen Permeability and Transmissibility by the Coulometric Method. Testing principal and testing instruments in ISO 9913-2 is very similar to that used in coulometric method in oxygen permeability testing of flexible material. Many manufacturers of contact lens have been authorizing Labthink to test the oxygen permeability of lens materials and have got ideal testing results.
    ISO 9913-2 is suitable for rigid and non-hydrogel flexible contact lens materials. The testing indexes are oxygen flux-j, oxygen permeability -Dk, oxygen transmissibility-Dk/t and specimen thickness-t. Generally, Dk is used to evaluate the permeability index of contact lenses. Testing principle is illustrated as fig. 1: put specimen into testing chamber to divide the chamber into upper and lower parts. Fill testing gas into upper chamber with the oxygen content at a fixed rate. Carrier gas flows into coulometric sensor from lower chamber, by which an equal pressure between two sides of the specimen is maintained. However, oxygen partial pressure is different. Under the function of partial pressure, oxygen will transmits into carrier gas through film and will be carried into coulometric sensor, where oxygen quantity in nitrogen gas can be calculated accurately and then oxygen transmissibility of the material can be calculated. Oxygen permeability instrument should be calibrated with reference film before testing to determine the calibration factor, which will be used in calibration. It is regulated in standard ISO 9913 that calibration specimen SRM 1470 is the same as that used in standard ASTM D 3985 for film testing.
    Testing process includes the following steps: purge system, diverge oxygen gas into upper chamber, sensor output becomes stable (judging whether transmitting achieves equilibrium), and obtain testing result. There are mainly two differences between testing of contact lenses and flexible package testing: one is the specimen fixture, specimen shape and area; the second difference is testing environment. Testing temperature of film oxygen permeability is 23. To simulate practical service condition, testing temperature of contact lenses is 35. Since temperature fluctuation has an obvious influence on testing results of oxygen permeability, the stability of testing temperature is of great significance. Therefore, it is better that the instruments possess function of temperature controlling, just as Labthink   OX2/230 Oxygen PermeabilityTester.

    3. Influence of Lenses Suitability on Oxygen Permeability
    
    Oxygen Transmission Rate Tester for Contact Lenses
    Oxygen Transmission Rate Tester for Contact Lenses
    
    Whether contact lenses are suitable mainly depends on the perfection of suitability.  A pair of good contact lenses should match with eye cornea perfectly. There is a layer of tear existing between contact lens and eye cornea, and is constantly flowing. The tears bring oxygen to cornea and take off waste substance. In this way, contact lenses will not change the normal physiological condition of eyes and will not impair eye cornea. If the contact lens doesn’t match well with eye cornea, even ultra thin lenses of high moisture content will adhere closely to the cornea with the result that the flowing of oxygen can only rely on moisture content and thickness of the lens. Of course, high oxygen permeability is always favorable, no matter what the kind of suitability is.

    4. Conclusion
    Oxygen permeability of contact lens, which has a direct influence on wearing comforts, is an important index. That is why manufacturers of various contact lenses are trying their best to improve oxygen permeability of contact lenses. At present, the marketing of PGP has obviously influenced market share of traditional flexible contact lenses. The outstanding merit of RGP is high oxygen permeability, which makes no oxygen deficit of eye cornea. With RGP, many complications caused by flexible contact lenses can be avoided. Therefore, RGP has become known and encouraged by most experts.


    Introduction for Barrier Properties in Instant Noodle’s Plastic Packages

    Because of its convenient to eat, rich taste, cheap price, long preservation, Instant noodle had well loved by people and become a convenient food all over the world. Instant noodles belongs to fried and dry food, which is easily oxidized and dampened. Once the instant noodles are oxidized, it will produce fatty acids and lead to excessive acid value, while dampened will influence its taste, lead to deteriorate or mildew, which cause quality accident in the consumption process. Therefore it is particularly important for barrier properties testing in instant noodles packaging.

    Labthink as the outstanding supplier in international packaging testing machine and testing services, combined with their own R&D barrier testing machine, Simple summarized the following packaging barrier performance testing method to guarantee the reliable quality.

    Barrier property refers to packaging materials’ barrier effect to gas, liquid and other penetrant. The barrier test include the transmission rate test of the gas(oxygen,  nitrogen, carbon dioxide)and water. The barrier properties are important factors affecting the quality of the product shelf life, and a vital reference to analyze the shelf-life..It can solved oxidative deterioration, sweat mildew and other problems due to oxygen or water vapor-sensitive



    Instant noodle, as an oil-fried food, its oil is mainly fats of animal or vegetables. which can easily produce fatty acid and result in excessive acid. During storage time, long time, high temperature, poor barrier property of packaging material all can result in instant noodles’ deterioration. which requires strict control of the oxygen barrier properties of packaging materials

    VAC Gas Permeability tester, Labthink’s R&D testing machine, based on the differential pressure method, It meet requirement of food packaging testing standards and carry out <GB / T 1038-2000 plastic film and sheet gas permeability test methods> standard, which can help enterprises to control the transmission rate of oxygen carbon dioxide and nitrogen ,etc. Labthink VAC gas Permeability tester choose good parts ,every indicators are better than the requirement of national or international standards. Gas transmission rate, solubility coefficient, diffusion coefficient, and permeability coefficient of the specimen could be obtained at one operation The instrument is controlled by a computer and test process is automatic.


    Related testing machines:

    Water Vapor Transmission Rate Test for Solar Backsheet

    With the development and usage of the renewable energy, along with the advocation and encourage of National policy, Solar backsheet,as a relatively mature cleaning energy, has been more and more used in industrial production and daily life. Solar modules are sequently  laminated by solar PV glass, EVA,  solar cells and solar backsheet. As the most outermost protective layer of the solar cell module, solar battery backsheet plays an important protecting and supporting role to battery piece and to be an important component of solar cell module. The service life of solar cell products is generally long .In order to meet the requirement, the backsheet material must not only have good weather resistance, shock resistance and reliable insulativity, but also have the higher water barrier performance. If the solar backsheet had the bad water barrier performance, then the humidity in air((especially rainy days more moisture) will pass through solar backsheet to inner side, and will affect the bonding properties of EVA  and result in the backsheet separating from EVA, and more moisture vapor directly contact with solar cells and make the cell oxidation, thus affecting the battery life. So the barrier performance is an important indicator to measure the performance of solar cell backsheet .It mainly reflected in the water vapor transmission rate data. The smaller the water vapor transmission rate, the better the water resistance.

    Next, We will have some simple introduction to solar backsheet ‘s water vapor permeation test combined with Labthink PERMETM W3/330 water vapor transmission rate testing system.
    
    http://upload.labthink.cn/Pictures/2011/Origin/w3-330-b.jpg
    W3/330 Water Vapor Transmission Rate Tester
    

    Water vapor transmission rate is the quality of water vapor through the unit area in unit timewhich is determined by the material’s barrier properties and the water vapor concentration of the material. Currently, Japan’s Sharp, Kyocera all have clear requirement to backssheet’s water vapor transmission rate indicator. Germany, Austria and other countries have the clear standard. Nowadays, most clients in the industry had generally adopt water vapor transmission rate testing principle of electrolysis method because its high-accuracy and good reliability.   

    Labthink’s R&D production W3/330 Water vapor transmission rate testing system ,adopting electrolysis test principle, structure design and excellent selection of components to make equipment with higher testing accuracy. and the control ability of temperature and humidity of environment is much higher than standard requirement, and provide a convenient and rapid calibration method as well. By the Patent cavity structure  design, the instrument can complete three kinds of same or different specimens test simultaneously, while using the host machine and satellite machine mode, a host can connect 9 satellite. which can achieve a maximum of 30 samples simultaneously to satisfy the testing demand for large laboratory test. And its application range is wide, which is suitable for water vapor transmission rate testing for plastic film. composite membrane, sheet material, high barrier materials, backplane, metal foil, waterproofing membrane, fabric, rubber, building materials ,the carton cardboard and solar backsheet

    While ensure the index of water vapor transmission rate of solar backsheet is standard, we must have control other indicators such as tensile strength and peel strength to ensure the quality of the products .About more information of the testing instrument, please see more details at www.labthink.cn .Labthink Instruments Co.,Ltd hopes to have further cooperation with the enterprises in all industry.
    
    http://www.labthink.cn/en/
    Labthink
    

    Monday, November 26, 2012

    Water Vapor Transmission Analyzer Labthink

     Water Vapor Transmission Analyzer Labthink is designed for the determination of water vapor transmission rate test of film and package specimens. It has three test modes and is applicable to various materials with high, medium and low water vapor permeability. Water Vapor Transmission Analyzer Labthink is also embedded with high precision infrared sensor, which provides a wide test range of 0.001~1000g/m2·24h and durable service life.                            
                                                  
    
    http://www.labthink.cn/en/product-info-water-vapor-transmission-rate-test-system-w3-330.html
    W3/330Water Vapor Transmission Analyzer
    
    1.Wide range and high-precision of automatic temperature and humidity control to support various combinations of non-standard test conditions
    2.Proportional, cycling and manual testing modes facilitate to test different materials with distinct water vapor permeability
    3.Save test data in different formats for convenient data transfer
    4. distinct or equivalent specimens can be tested individually with independent test results at one operation
                                    

     Applications
    1.Films
    2.Sheet
    3.Paper and Paper Board
    4.Packages

    Technical Specifications:
    Number of Specimen : 3 (Independent results for each specimen)
    Temperature Accuracy;±0.1°C (standard)
    Humidity Accuracy; ±1%RH

    Water Vapor Transmission Analyzer Labthink conforms to the following standards:
    ISO 15106-2, ASTM F1249, TAPPI T557, JIS K7129

    ISO 15106-2 - Plastics -- Film and sheeting -- Determination of water vapour transmission rate -- Part 2: Infrared detection sensor method
    ASTM F1249 - Standard Test Method for Water Vapor Transmission Rate Through Plastic Film and Sheeting Using a Modulated Infrared Sensor
    TAPPI T557 - Water vapor transmission rate through plastic films and sheeting using a modulated infrared sensor

    Related products:  W3/230 Water Vapor Transmission Rate Tester
                                W3/030 Water Vapor Transmission Analyzer
                                W3/060 Water Vapor Transmission Analyzer
                                W3/0120 Water Vapor Transmission Analyzer



    Thursday, November 22, 2012

    Barrier Performance Test in Cooking Oil Barrel

    Cooking oil is the necessity in our life, It is an important food which can supply body heat and essential fatty acid as well as promote the absorption of fat-soluble vitamins. To measure the nutritional value of the edible oil, there are two indices, i.e. Content of unsaturated fatty acid and essential fatty acids. But the fatty acid is prone to rancidity reactions and finally lead to oil deterioration.So Barrier Performance Test in Cooking Oil Barrel is especially important .

    
    OX2/230
    OX2/230
    
    The rancidity of Cooking oil is an natural phenomenon, We can only reduce the speed of the rancidity and can't stop grease rancidity. So It is inadvisable to buy too much cooking oil and store for a long time, In addition, if we want to reduce the edible oil’s rancidity speed in shelf and storage Period, on one hand, It must be stored in dark and low temperature. on the other hand, grease’s packing containers - Cooking oil barrel, must have higher sealing barrier properties, especially the ability to cut off water vapor and air

    
    http://upload.labthink.cn/Pictures/2011/Origin/w3-330-b.jpg
    W3/330
    
    According to the customer commissioned, Labthink Laboratory recently had done some barrier property test of different material in Cooking Oil Barrel. Adopted standard Configuration of Perme OX2/230 oxygen transmission rate test system and Perme W3/330 water vapor transmission rate test system, Labthink had accomplished 4L and below capacity edible oil barrel’s barrier performance testing. But the container of 5L and larger size need to customize temperature control devices to do temperature control test  and the barrier performance test under the conditions in laboratory environment.

    

    Labthink, focusing on the laboratory testing instruments R&D and production and laboratory IT services, is dedicated to provide professional quality control solutions for customers in packaging, food, pharmaceutical, medical, daily chemistry, printing, adhesive, automotive, petrochemistry, bioscience, construction, new energy and other industries.

    Tensile Testing Machine for Pet Strap/PP Strap

    Tensile Testing Machine for Pet Strap/PP Strap  is professionally applicable to the determination of force properties of various flexible packaging materials, with high precision (better than 0.5% of reading accuracy) and multiple test ranges.  Tensile Testing Machine for Pet Strap/PP Strap is designed with 7 independent test modes and could perform tests at seven different test speeds to meet various test conditions. Intelligent software facilitates to operate the instrument and provides data analysis and comparison functions.

    • Better than 0.5% of reading accuracy effectively ensures accurate test results
    • 7 independent test modes are available, including tensile strength, peeling force, tearing force and other force properties of flexible packages
    • 1000mm extra-long stroke satisfies the test needs of various materials with extreme deformation rate
    • Different test range of load cells and 7distinct test speeds to meet different test requirements
    • Tensile Testing Machine for Pet Strap/PP Strap is controlled by a micro-computer with menu interface, PVC operation panel and large LCD display
    Applications :
    • Tensile Property
    • Tensile Testing Machine for Pet Strap/PP Strap
    • Test of Tensile Strength and Elongation Rate
    • Test of Tensile Strength at Break
    • Tear Resistance Test
    • Heat Seal Strength Test
    • 90 Degree Peel Test
    • 180 Degree Peel Test
    Technical Specifications:

    • Test Range:500N,50N(one of them is available)
    • Accuracy:<0.5% of reading value
    • Number of Specimens:1
    • Stroke:1000mm
    • Net Weight:68kg
    Tensile Testing Machine for Pet Strap/PP Strap conforms to various national and international standards as follows: ISO 37, GB 8808, GB/T 1040.1-2006, GB/T 1040.2-2006, GB/T 1040.3-2006, GB/T 1040.4-2006, GB/T 1040.5-2008, GB/T4850-2002, GB/T12914-2008, GB/T 17200, GB/T 16578.1-2008, GB/T 7122, GB/T 2790, GB/T 2791, GB/T 2792, ASTM E4, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, JIS P8113, QB/T 2358, QB/T 1130 

    Labthink,Think for you only!